Installing HMP155 - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide

Install HMP155 on a support arm approximately 2 m (7 ft) from the ground.

In airport applications, the humidity and temperature probe must be installed exactly 2 m (7 ft) from the ground.

You can install the optional T‑probe inside radiation shield DTR13 with HMP155.

WARNING Do not perform installation or maintenance procedures when there is a risk of thunderstorm or lightning activity in the area.
CAUTION The radiation shield is important in protecting the sensor head from rain and splashing water and must always be used.
To prevent corrosion, oxidation, and seizing, use a non‑conductive, non‑water‑soluble, non‑silicone‑based grease, such as ceramic or Teflon paste, between different kinds of metal.