FP2000 cable wiring - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide

The FP2000 Type IIA cable is fixed to the sensor. The cable can be lengthened by splicing it with a Type V extension cable.

FP2000 Type IIA cable
Sensor code Cable length Number of wires DRI701 slot
76420300 91.44 m (300 ft) 8 + shield 1

ROAD SENSOR 1

(first sensor)

76420500
76421300 152.40 m (500 ft)

ROAD SENSOR 2

(second sensor)

76421500
FP2000 Type IIA cable termination to 16‑pin connector
Signal Wire color DRI701 connector pin Wire color Signal
Range indicator Orange 16 8 Green Control line
Sensor out Blue 15 7 Black −12 V
Not connected 14 6 Not connected
Thermistor − Gray/White 13 5 Brown Ground
Thermistor + White 12 4 Not connected
Not connected 11 3 Red +12 V
Not connected 10 2 Not connected
Not connected 9 1 Not connected
FP2000 Type IIA cable shield
Color Usage Action
Shield (clear or brown) Ground

Connect to enclosure sensor grounding rail.

FP2000 Type IIA wiring
1 Calculated after cutting the cable.