SP Lite2 cable wiring - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide

The global radiation sensor is always connected to the first DRI701 card.

SP Lite2 cable
Cable code Cable length Number of wires DRI701 slot
Fixed cable 15 m (49 ft 3 in) 2 + shield 1 SENSOR (on the left)
SP Lite2 cable termination to 8‑pin connector
Signal Wire color PMU701 connector pin Wire color Signal
R − Blue 2 8 4 Not connected
R − Blue 7 3 Not connected
R + Red 6 2 Not connected
Not connected 5 1 Not connected
SP Lite2 cable shield
Color Usage Action
Shield Ground

Connect to enclosure sensor grounding rail.

SP Lite2 wiring
1 Calculated after cutting the cable.
2 Use a 5‑cm (2‑in) piece of blue wire to connect pins 7 and 8.