DTS210 cable wiring - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide

The DTS210 Type IIA cable is fixed to the sensor. The cable can be lengthened by splicing it with a Type V extension cable.

If you have two DTS210 sensors, mirror the connections on the left side of the connector.

DTS210 type IIA cable
Cable code Cable length Number of wires DRI701 slot
Fixed cable 8 + shield 1

SENSOR

(first sensor on the right)

(second sensor on the left)

DTS210 Type IIA cable termination to 8-pin connector

Signal

Sensor 2

Wire color

Sensor 2

DRI701 connector pin

Wire color

Sensor 1

Signal

Sensor 1

Thermistor − Gray/White 8 4 Gray/White Thermistor −
Thermistor + White 7 3 White Thermistor +
Not connected 6 2 Not connected
Not connected 5 1 Not connected
DTS210 Type IIA cable shield and unused wires
Color Usage Action
Shield Ground

Connect to enclosure sensor grounding rail.

Black Not used Cut.
Red
Orange
Brown
Blue
Green
DTS210 Type IIA wiring
1 Calculated after cutting the cable.