AQT560 cable wiring - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide
AQT560 cables
Cable code Cable length Number of wires PMU701 slot
223283 5 m (16 ft 9 in) 8 + shield 1 G2
220497 10 m (32 ft 10 in)
AQT560 cable termination to 10‑pin connector
Signal Wire color PMU701 connector pin Wire color Signal
Not connected 10 5 Not connected
Not connected 9 4 Not connected
Not connected 8 3 Not connected
Power in +12 V Red 7 2 Gray RS‑485 D−
Ground Blue 6 1 Pink RS‑485 D+
AQT560 cable shield and unused wires
Color Usage Action
Shield Ground

Connect to PMU701 sensor grounding rail.

White Service port (RS‑232 ground)

Cut to different lengths and tie together with electrical tape.

Green Service port (RS‑232 RX output)
Brown Service port (RS‑232 RX input)
Yellow Not used Cut and insulate with electrical tape.
AQT560 wiring
1 Calculated after cutting the cable.