| Cable code | Cable length | Number of wires | PMU701 slot |
|---|---|---|---|
| 216546 | 10 m (32 ft 10 in) | 5 + shield 1 | D2 (first sensor) |
| 216547 | 25 m (82 ft) | E2 (second sensor) | |
| DR221741Z50M | 50 m (164 ft 1 in) | ||
| DR221741Z100M | 100 m (328 ft 1 in) | ||
| DR221741Z150M | 150 m (492 ft 2 in) |
| Signal | Wire color | PMU701 connector pin | Wire color | Signal | |
|---|---|---|---|---|---|
| Ground | Gray | 10 | 5 | Blue | Ground |
| Not connected | – | 9 | 4 | Black | RS-485 D− |
| Power in +9 … 30 V | Brown | 8 | 3 | White | RS-485 D+ |
| Not connected | – | 7 | 2 | – | Not connected |
| Not connected | – | 6 | 1 | – | Not connected |
| Color | Usage | Action |
|---|---|---|
| Shield | Ground |
Connect to PMU701 sensor grounding rail. |
1 Calculated after cutting the cable.