DRS511 cable wiring - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide

The DRS511 cable is fixed to the sensor.

The cable has twisted-pair wires where one of the wires is always white and the other is colored. The color indicates the purpose of the pair. Each pair also contains a shield. In an uncut cable, the shield is inside a clear wire.

To keep track of the pairing, braid the wires together before connecting them.

The cable can be lengthened by splicing it with a Type V extension cable.

DRS511 cables
Sensor code Cable length Number of wires DRI701 slot
DRS511AB2/DRS511BB2 20 m (65 ft 7 in) 4 × (twisted pair + shield) 1

ROAD SENSOR 1

(first sensor)

DRS511AB3/DRS511BB3 30 m (98 ft 5 in)

ROAD SENSOR 2

(second sensor)

DRS511AB5/DRS511BB5 50 m (164 ft 1 in)
DRS511AB10/DRS511BB10 100 m (328 ft 1 in)
DRS511AB15/DRS511BB15 150 m (492 ft 2 in)
DRS511AB20/DRS511BB20 200 m (656 ft 2 in)
DRS511AB30/DRS511BB30 300 m (984 ft 3 in)
DRS511 cable termination to 16‑pin connector
Signal Wire color DRI701 connector pin Wire color Signal
Not connected 16 8 Not connected
Not connected 15 7 Not connected
Ground 2 Shield or clear 14 6 Shield or clear Ground 2
Ground 2 Shield or clear 13 5 Shield or clear Ground 2
TG− (Pt100) Brown 12 4 Orange Frequency out
TS/TG common (Pt100) White (paired with brown) 11 3 White (paired with orange) +VB for opto sensor
TS+ (Pt100) Blue 10 2 Green Conductivity in
Pt100 excitation White (paired with blue) 9 1 White (paired with green) Conductivity out
DRS511 wiring
1 Calculated after cutting the cable.