The Type V cable is an extension for the fixed sensor cable.
| Extension cable maximum length | Number of wires | DRI701 slot |
|---|---|---|
| 1524 m (5000 ft) 1 | 6 twisted pairs + shield 2 |
ROAD SENSOR 1 (first sensor) |
|
ROAD SENSOR 2 (second sensor) |
| Signal | Wire color | DRI701 connector pin | Wire color | Signal | |
|---|---|---|---|---|---|
| Not connected | – | 16 | 8 | – | Not connected |
| Not connected | – | 15 | 7 | – | Not connected |
| Ground | White (paired with gray) | 14 | 6 | Cut a piece of extra wire, insert it into pin 6, and wrap the other end around the stud of the shield bond connector | Ground |
| Ground | Blue (paired with red) | 13 | 5 | Gray | Ground |
| TG− (Pt100) | Brown | 12 | 4 | Orange | Frequency out |
| TS/TG common (Pt100), Pt100 excitation | White (paired with brown), white (paired with blue) 3 | 11 | 3 | White (paired with orange) | +VB for opto |
| TS+ (Pt100) | Blue | 10 | 2 | Green | Conductivity in |
| TS+ (Pt100) | Red (paired with blue) | 9 | 1 | White (paired with green) | Conductivity out |
| Color | Usage | Action |
|---|---|---|
| Shield | Ground |
Connect to enclosure sensor grounding rail. |
1 Manufacturer: General
Cable, cable type: filled solid cable RDUP (RUS) PE‑39 AL, 6 pairs
(AWG 19).
2 Calculated after
cutting the cable.
3 Twist the wires together and insert them into the pin.