Overview of enclosure installation - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide

The enclosure houses the system components for the weather station. The wiring inside the enclosure is done at Vaisala.

Install the enclosure so that the bottom comes roughly 1 m (3 ft 3 in) from the ground which is eye height for best working access.

Before installing the enclosure, ensure that all sensors are already installed.

See the relevant instructions:

For the installation weight, see the appendix.

WARNING The enclosure unit is heavy and contains sensitive equipment. Exercise caution when mounting the enclosure to avoid personnel injury and damage to the enclosure.
WARNING For safety reasons, do not install the enclosure alone. Safe installation requires at least 2 people.
WARNING A long cable between units (sensors, transmitters, power supplies, and displays) can cause a lethal lightning-induced current surge. Always ground the enclosure to a suitable grounded location with a short, low-resistance cable.
WARNING When installing the backplate without the enclosure, ground the backplate to the local grounding connector with a low impedance connection. Vaisala recommends 6 mm2 (10 AWG) or heavier copper wire.
To prevent corrosion, oxidation, and seizing, use a non‑conductive, non‑water‑soluble, non‑silicone‑based grease, such as ceramic or Teflon paste, between different kinds of metal.