Preparing splice kit - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide
Wear the provided gloves when placing the cables in the splice enclosure.
  1. Remove the plastic bag covering the splice enclosure.
  2. Lay the cables inside the splice enclosure. Fold over the wires to better fit them inside the enclosure.
  3. Peel off the protective papers between the splice enclosure halves.
  4. Close the splice enclosure.
    1. To force the splice and cables into the sealant, push the 2 halves of the splice enclosure together as tight as possible.
    2. To squeeze the halves together, slide the V-notched end of the closing clamp towards the cable end of the splice kit.
    3. Tapping the closing clamp with a mallet, slide the closing clamp along the enclosure to squeeze the halves together.

      Continue tapping until fully closed.

      Tap the closing clamp slowly to allow excess sealant to extrude from the enclosure.
    4. Wipe off any extruding sealant if needed.
  5. Insert the splice enclosure into the splice hole.