Mounting R.M. Young Wind Monitor on support arm - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide
5‑mm Allen key
  1. Install the SENSORARMFIX60 mounting bracket on the support arm. Tightening torque 5 Nm.
    1
    Ø 60 mm (2.36 in) bracket
    2
    Sensor bar fixture part
    3
    Hex screw M6×60 DIN912 A4 (2 pcs)
    4
    Spring washer A6 DIN127 A4 (2 pcs)
  2. Lead the sensor cable through the opening on the RMYFIX60 mounting bracket and through the SENSORARMFIX60 mounting bracket.
  3. Insert the sensor on the mounting bracket and tighten the installation bolt. Tightening torque 5 Nm.
  4. Align the sensor.

    See R.M. Young Wind Monitor configuration instructions in RWS200 Configuration and Maintenance Manual (M211803EN).

Write down the sensor installation height. This is needed for the metadata in the Web UI.