Mounting WXT530 on support arm - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide
2.5‑mm and 5‑mm Allen keys
WXT530 (WXT536) support arm installation accessories
1
WXT530 mounting kit (212792)
2
Mounting adapter (WMSFIX60)
3
Support arm mounting bracket (SENSORARMFIX60)
CAUTION Handle with care. Any impact on the instrument or sensor array may cause damage and lead to incorrect measurements.
  1. Remove the adapter sleeve from the WXT530 mounting kit.
  2. Lead the sensor cable through the WXT530 mounting kit, and connect the cable to the bottom part of the sensor.
  3. Push the WXT530 mounting kit to the bottom part of the sensor, and turn the kit until it snaps to position.
  4. Install the SENSORARMFIX60 mounting bracket on the support arm. Tightening torque 5 Nm.
    1
    Ø 60 mm (2.36 in) bracket
    2
    Sensor bar fixture part
    3
    Hex screw M6×60 DIN912 A4 (2 pcs)
    4
    Spring washer A6 DIN127 A4 (2 pcs)
  5. Install the mounting adapter on the mounting bracket, and tighten the installation screw. Tightening torque 5 Nm.
    1
    Mounting adapter
    2
    Hose clamp
    3
    Hex screw M6×55 DIN912 A4
    4
    Mounting bracket
  6. Haul the sensor up.
  7. Holding the sensor from its body, run the sensor cable through the mounting adapter, and slide the sensor onto the adapter. Do not tighten the fixing screw yet.
    1
    Fixing screw. Tightening torque 1.5 Nm.
    2
    Mounting adapter
    3
    Mounting kit
  8. Align the sensor.