Mounting ENC722 on thick pole mast - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide
  • Tin snips
  • 5‑mm Allen key

To mount the enclosure to a 80–600 mm (3.15–23.62 in) pole mast, use the DRUNIV‑US mounting kit. To attach the mounting kit, use any suitable stainless steel band and locks, for example, BAND‑IT 19.1 mm (0.75 in) with Ear‑Lokt buckles. Because most steel bands require special tools, if you only need the band for a few installations, use the DRUNIV mounting kit that includes the band and locks.

On a wooden pole, you can use hot-galvanized lag bolts instead of stainless steel band.

ENC722 and DRUNIV mounting kit
1
DRUNIV mounting support (2 pcs)
1.1
Spring washer B6 DIN127 A4 (8 pcs)
1.2
Hex screw M6×16 DIN912 A4 (8 pcs)
2
Stainless steel band and locking mechanism (2 pcs) (not included in DRUNIV‑US mounting kit)
ENC722 mounting frame for DRUNIV‑US mounting kit (front)
1
Enclosure mounting slot (2 pcs)
2
Hole for enclosure mounting screw (2 pcs)
3
Hole for DRUNIV mounting support (8 pcs)
  1. Measure and mark the place where the upper clamp is to be installed.

    To mount the enclosure at eye height, place the bottom of the upper clamp approximately 1.45 m (4 ft 9 in) from the ground.

  2. Cut the stainless steel band into suitable pieces.
  3. Place the upper mounting clamp on the pole and attach it with the stainless steel bands.

    To make sure that the mounting clamp is firmly attached, avoid large gaps between the pole and the band. Thread the band through the holes that are closest to the pole in the mounting clamp. Between the holes, tighten the band to the pole.

    a)
    5 cm (1.97 in) from the top of the clamp to the radiation shield
    b)
    1 cm (0.39 in) from the top of the clamp to the top of the mounting frame
  4. Attach the lower mounting clamp to the mounting frame. Tightening torque 5 Nm.
    1
    Spring washer B6 DIN127 A4 (8 pcs)
    2
    Hex screw M6×16 DIN912 A4 (8 pcs)
  5. Attach the mounting frame to the upper mounting clamp. Tightening torque 5 Nm.
    1
    Spring washer B6 DIN127 A4 (8 pcs)
    2
    Hex screw M6×16 DIN912 A4 (8 pcs)
  6. Fasten the lower mounting clamp to the pole mast.
  7. Lift the enclosure by holding it from the ceiling and the bottom of the enclosure.
  8. Hang the enclosure onto the frame by sliding the mounting studs on the back of the enclosure into the mounting slots of the frame.
    1
    Washer with EPDM gasket 6.8/16×1.5/A2/EPDM (2 pcs)
    2
    Hex screw M6×16 ISO7380 A4 (2 pcs)
  9. Attach the enclosure to the mounting frame. Tightening torque 5 Nm.
1 Electronics not shown