Creating Calculation Presets - BLVIEW - CL31 - CL51

BL‑View User Guide

Document code
M211185EN
Revision
E
Language
English
Product
BLVIEW
CL31
CL51
Document type
User guide

You can create calculation presets to use in plots.

Saving a new or an edited preset closes all open plots except the live default plot and resets the view.
  1. In BL-View, select System > Settings > Presets.
  2. To create a new preset, select Create new, type a name, and select OK.

    In the Settings window, set the following:

    Algorithm method
    Select Merged Gradient and profile fit, Gradient, or Profile fit.
    Advanced algorithm settings
    For information about modifying advanced algorithm settings, see Modifying Algorithm Settings of Calculation Presets.
    Boundary layer min
    Set the lowest reported boundary layer height. The available range is 30 … 500 m (99 … 1640 ft). The default value is 30 m (99 ft).
    Boundary layer max
    Set the highest reported boundary layer height. The available range is 200 … 4000 m (656 ... 13 120 ft). The default value is 4000 m (13 120 ft).
    Number of boundary layers
    Set the maximum number of boundary layers shown in BL-View. The available range is 1 … 3. The default value is 3.
    Time averaging
    Select defined by User and set the time averaging interval. The default value is 30 minutes.
    Height averaging
    Select defined by User and set the height averaging interval. The default value is 360 m (1181 ft).
  3. Select Save and Close.
To use the new preset, select Add Plot and for Preset select the preset you created.