Connector plate (optional) - WID511

WID511 User Guide

Document code
M211109EN
Revision
L
Language
English
Product
WID511
Document type
User guide
If you are using the connector plate, not all figures in Connecting cables and grounding apply.
Figure 1. Connecting cables to connector plate
1
Power connector
2
RS‑485 signal connector
3
Power connector slot +. Connect to + on the power cable.
4
Power connector slot (ground). Connect to on the power cable.
5
Signal connector slot 1. Connect to R/D− on the data cable.
6
Signal connector slot 2. Connect to R/D+ on the data cable.
If the display is delivered with the optional connector plate, the DIP switches are set to the RS‑485 2‑wire mode already at the Vaisala factory. If you install the connector plate after the delivery, set the DIP switches to the RS‑485 2‑wire mode yourself.