Register number | Address | Register description | Data format | Unit |
---|---|---|---|---|
Floating point values | ||||
1 | 0000hex | Relative humidity | 32-bit float | %RH |
0001hex | ||||
3 | 0002hex | Temperature 1 | 32-bit float | °C |
0003hex | ||||
9 | 0008hex | Dew/frost point temperature | 32-bit float | °C |
0009hex | ||||
15 | 000Ehex | Absolute humidity | 32-bit float | g/m3 |
000Fhex | ||||
17 | 0010hex | Mixing ratio | 32-bit float | g/kg |
0011hex | ||||
19 | 0012hex | Wet-bulb temperature | 32-bit float | °C |
0013hex | ||||
27 | 001Ahex | Enthalpy | 32-bit float | kJ/kg |
001Bhex | ||||
Integer values | ||||
257 | 0100hex | Relative humidity | 16-bit integer | %RH * 10 |
258 | 0101hex | Temperature 1 | 16-bit integer | °C * 10 |
261 | 0104hex | Dew/frost point temperature | 16-bit integer | °C * 10 |
264 | 0107hex | Absolute humidity | 16-bit integer | g/m3 * 10 |
265 | 0108hex | Mixing ratio | 16-bit integer | g/kg * 10 |
266 | 0109hex | Wet-bulb temperature | 16-bit integer | °C * 10 |
270 | 010Dhex | Enthalpy | 16-bit integer | kJ/kg * 10 |
1 Only temperature output is available in probe model HMP110T.