Set Analog Output Mode - HMM100

HMM100 User Guide

Document code
M211024EN
Revision
E
Language
English
Product
HMM100
Document type
User guide
AMODE [mode]<cr>
mode
Analog output mode.

Use the AMODE command to show or set the operation mode of the analog output. This command is only needed with the 3-wire output module, as the output on the 2-wire model is always 4 ... 20 mA (loop powered).

If you change the analog output mode, you must calibrate the new mode using the ACAL command. See Calibrate Analog Output.
Modes for 3-wire output model:
  • 0..1V
  • 0..5V
  • 0..10V
  • 0..20mA
  • 4..20mA
Modes for 2-wire output model:
  • 4..20mA
Remember to save the changes!
Example (show current mode):
>amode
Ch1 :   0..10V
>save
Saving settings...done
>
Example (set mode to 0..20 mA):
>amode 0..20ma
Ch1 :   0..20MA
>save
Saving settings...done
>