A log entry is generated at the time defined in the setup file. When you retrieve entries with the logshow command, the output includes the header and the log entry information.
The header information shows the variable name (WindSim:outputVar1 and WindSim:outputVar2). The log entry information includes the time tag, that is, date and time of the entry, the status, and the value of the logged measurement or calculation.
Status indicator | Status | Description |
---|---|---|
-I----- |
Invalid | The value may be outside the set scale; that is, the set climatological limits or step change validation. |
-I--N- |
Invalid; not available | No measurements done yet. |
V----- |
Valid (normal) | Measurement or calculated value available normally. |