Restarting the QML data logger with a blank setup may be useful if the setup is somehow defective and does not allow the opening of a service connection. When you restart with a blank setup, the serial port settings of the QML data logger are restored to their defaults: COM0, 9600, N, 8, N, 1.
Before restarting with a blank setup, contact Vaisala to get a new setup file that you can upload to the QML data logger.
  1. Open the cover of the QML data logger.
  2. Press and keep the reset button pressed down for a few seconds.

    The QML logger restarts and displays the text Using blank configuration.