| Property | Description/Value |
|---|---|
|
Operating temperature |
−52 … +70 °C (−60 … +158 °F) |
|
Storage temperature |
−52 … +70 °C (−60 … +158 °F) |
| Installation temperature |
−40 … +70 °C (−40 … +158 °F) |
| Maintenance work temperature |
−40 … +70 °C (−40 … +158 °F) |
| Property | Description/Value |
|---|---|
| Input voltage 1 |
Power channels: max. ±43 V Data channels: max. ±13 V |
| Input common mode voltage | Any line to earth: max. ±72 V |
| Throughput current |
Power lines: max. 1.5 A Data lines: max. 0.16 A |
| Throughput resistance (per line) |
Power lines: max. 0.3 Ω Data lines: max. 15 Ω |
| Turn-on voltage |
Power channels: max. ±60 V Data channels: max. ±16 V |
| Surge current |
To earth: max. 10 kA Differential: max. 5 kA |
| Property | Description/Value |
|---|---|
| Weight | 0.65 kg (1.43 lb) |
| Housing material | Polycarbonate, stainless steel |
| Housing dimensions (H × W × D) | 94 × 130 × 58 mm (3.70 × 5.12 × 2.28 in) |
| Dimensions with cable glands and mounting assembly (H × W × D) | 112 × 130 × 69 mm (4.41 × 5.12 × 2.72 in) |
| Cables (Ø) | 5–10 mm (0.20–0.39 in) |
| Wires (Ø) | 0.4–1.7 mm (0.016–0.067 in) (AWG 26–14) |
| Property | Description/Value |
|---|---|
| EMC surge tolerance |
EN 61000-4-5 (4 kV, 2 kA) IEEE C62.45 (6 kV, 3 kA) |
|
IP rating |
IP66: Dust-tight. Protected from powerful water jets from any direction. |
|
NEMA 250 rating |
Type 4X: Dust-tight. Protected from corrosion and hose-directed water. |
|
Compliance marks |
CE, China RoHS, RCM |
1 Across channel line pair and from line to GND, terminals
#3