Wiring WSP150 - WSP150

WSP150 Quick Guide

Product status
Document code
M210809EN-E
ft:locale
en-US
Product
WSP150
Document type
User guide
  • Tools and accessories for wiring
  • 8-mm wrench (for fixing crimp connector)
WARNING Only licensed experts may install electrical components. They must adhere to local and state legislation and regulations.
WARNING Make sure that you prepare or connect only de-energized wires.
WARNING Keep away from live circuits. Operating personnel must observe safety regulations at all times.
WARNING Do not operate in an explosive atmosphere, for example, when flammable gases or fumes are present. Operation of electrical equipment in such an environment constitutes a safety hazard.
CAUTION Do not damage or change the wiring. Incorrect wiring can cause damage and prevent or limit operation.

Signal names are for RM60. In other products, signal names and wire colors can vary.

To create jumpers for RS-232 and SDI-12 connections, use the pieces of wire provided with WSP150.

If you have common wires for heating and operating voltages on the system side, connect the following terminals in parallel:

  • 1 and 3
  • 2 and 4

Vaisala recommends using a device cable with a maximum length of 3 m (10 ft).

Wiring abbreviations
Signal Description
VH+, VH− Heating voltage
V+, V− Operating voltage
SG Signal ground
TX+, TX−, TXD Transmitted data
RX+, RX−, RXD Received data
D+, D− 2-way data
Iout1, Iout2 Current output
Wiring with SDI-12, RS-232, RS-422 (2-wire and 4-wire), and RS-485
Wiring WSP150 with WXT532 with 2 x 4-20mA outputs
  1. Open the 4 plastic screws and remove the enclosure cover.
  2. Enter the line cable through the left side cable gland and make the wiring to the line terminals.
    For best shielding from RF interference, bend the output cable shield over the plastic sleeve and O-ring and tighten the line cable gland carefully.
  3. Enter the device cable through the right side cable gland and make the wiring to the device terminals. Carefully tighten the device cable gland.
  4. Reattach the enclosure cover with the 4 plastic screws.
  5. If the mast (or its surface or base) is poorly conductive, use a grounding wire. Connect the grounding wire end to the crimp connector provided in the plastic bag. Fix the crimp connector with the M5 nut and washer to the grounding screw at the rear upper left corner of the enclosure.
    CAUTION To minimize surge induction to the cable, make sure the device cable is short. Ground the enclosure through the mast or with a 16 mm2 (5 AWG) copper wire from the grounding screw to true earth (lightning ground).