Property | Description/Value |
---|---|
Operating environment | |
Operating temperature | −10 ... +40 °C (+14 … +104 °F) |
Operating humidity | 0 ... 100 %RH, non-condensing |
Storage temperature | −40 ... +70 °C (-40 ... +158 °F) |
Inputs and outputs | |
Max. no of probes | 2 |
PC interface | MI70 Link software with USB or serial port cable |
Power supply | Rechargeable NiMH battery pack with AC adapter or 4 × AA size alkalines, type IEC LR6 |
Analog output: 1 | |
Scale | 0 ... 1 V DC |
Output resolution | 0.6 mV |
Accuracy | 0.2 % full scale |
Temperature dependence | 0.002 %/˚C (0.01 %/˚F) full scale |
Minimum load resistor | 10 kΩ to ground |
Mechanical specifications | |
Housing classification |
IP54: Limited protection against dust. Protected from water splashes from any direction. |
Housing materials | ABS/PC blend |
Weight | 400 g (14 oz) |
Compatibility | |
EMC compliance | EN 61326-1, portable equipment |
Other | |
Menu languages | English, Chinese, Spanish, Russian, French, Japanese, German, Swedish, Finnish |
Display |
LCD with backlight Graphic trend display of any parameter Character height up to 16 mm (0.63 in) |
Alarm | Audible alarm function |
Data logging capacity | 2700 real time data points |
Logging interval | 1 s to 12 h |
Logging duration | 1 min ... memory full |
Resolution | 0.01 %RH, 0.01 °C/°F, 0.01 hPa, 0.01 aw, 10 ppm / 0.01 %CO2 |
Property | Value/Description |
---|---|
Typical charging time | 4 hours |
Operation times | |
Continuous use (with handle) | Better than 8 h at +20 ˚C (+68 °F) |
Continuous use (with pump) | Better than 5 h at +20 ˚C (+68 °F) without load |
Data logging use (one probe) | Up to 30 days depending on logging interval |
1 The
specifications apply only when analog output is enabled for the handheld
meter.