Model |
Description |
---|---|
AFC |
Elbow flow cell |
Sensor connection |
|
‑H |
Sanitary clamp, 2.5 in |
Material of construction |
|
SS |
AISI 316 L |
Process connection |
|
‑H |
Sanitary clamp |
Pipe section diameter |
|
10 |
25 mm (1 in) |
15 |
40 mm (1.5 in) |
20 |
50 mm (2 in) |
25 |
65 mm (2.5 in) 1 |
30 |
80 mm (3 in) 1 |
40 |
100 mm (4 in) 1 |
Flow cell inlet type |
|
‑SI |
Straight pipe |
‑RI |
Reduced pipe (cone) |
Polishing option |
|
‑EP |
Electropolished process wetted parts (RA 0.38 µm, 15 µin) |
Model |
Description |
---|---|
AFC |
Elbow flow cell |
Sensor connection |
|
‑H |
Sanitary clamp, 2.5 in |
Material of construction |
|
SS |
AISI 316 L |
Process connection |
|
‑H |
Sanitary clamp |
Pipe section diameter |
|
20 |
50 mm (2 in) |
Flow cell inlet type |
|
‑SI |
Straight pipe |
EHEDG |
|
‑EH |
EHEDG Type EL Class I Certified Model |
Model |
Description |
---|---|
AFC |
Elbow flow cell |
Sensor connection |
|
‑H |
Sanitary clamp, 2.5 in |
Material of construction |
|
SS |
AISI 316 L |
Process connection |
|
‑H |
Sanitary clamp |
Pipe section diameter |
|
10 |
25 mm (1 in) |
15 |
40 mm (1.5 in) |
20 |
50 mm (2 in) |
25 |
65 mm (2.5 in) 2 |
30 |
80 mm (3 in) 2 |
40 |
100 mm (4 in) 2 |
Flow cell inlet type |
|
‑SI |
Straight pipe |
‑RI |
Reduced pipe (cone) |
Wash nozzle connection |
|
‑NC |
Nozzle connection |
Wash nozzles |
|
‑SN |
Steam nozzle, G¼ thread female |
‑WN |
Water nozzle, G¼ thread female |
‑WP |
Pressurized water nozzle, G¼ thread female |
‑PG |
Plug for nozzle connection |
Model |
Description |
---|---|
MFC |
Mini flow cell |
Sensor connection |
|
‑H |
Sanitary clamp, 2.5 in |
Material of construction |
|
SS |
AISI 316 L |
Process connection |
|
‑H |
Sanitary clamp |
Pipe section diameter |
|
05 |
15 mm (0.5 in) |
Model |
Description |
---|---|
TDN |
Varinline® in‑line access unit clamp DN65 Type N 3 |
Pipe section diameter |
|
‑40 |
40 mm (1.5 in) |
‑50 |
50 mm (2 in) |
‑65 |
65 mm (2.5 in) |
‑80 |
80 mm (3 in) |
‑100 |
100 mm (4 in) |
‑125 | 125 mm (5 in) |
‑150 | 150 mm (6 in) |
Counter flange options | |
‑SN |
Steam nozzle, G¼ thread female |
‑WP |
Pressurized water nozzle, G¼ thread female |
‑WN |
Water nozzle, G¼ thread female |
‑PG |
Varivent blind flange type N |
Model |
Description |
---|---|
SFC |
Side flow cell 4 |
Sensor connection |
|
‑H |
Sanitary clamp, 2.5 in |
Material of construction |
|
SS |
AISI 316 L |
Process connection |
|
‑H |
Sanitary clamp |
Pipe section diameter |
|
10 |
25 mm (1 in) |
15 |
40 mm (1.5 in) |
20 |
50 mm (2 in) |
25 |
65 mm (2.5 in) |
Flow cell inlet and outlet orientation |
|
‑90 |
Elbow, 90° bend |
‑180 |
Straight pipe, 180° |