Transmitter card positions and Motherboard PR‑10600 and H1 interface card PR‑10701 assist in locating the diagnostic LEDs.

Diagnostic LEDs
LED Status Indication See section
Front panel
Green LED Lit DTR power is on; processor card PR‑10500 is active. Blank display
Transmitter processor card PR‑10500
2 yellow LEDs Blinking Processor card OK
Transmitter motherboard PR‑10600
Yellow LED (D17) Blinking Motherboard processor working.
Green LED (D16) Lit Processor card converts 24 V / 3 V.
Green LED (D26) Lit Isolating DC / DC conversion OK.
2 green LEDs (D23, D25) Lit Corresponding relay (RLY1 / RLY2) has power.
H1 interface card PR‑10701
Green LED (LD1) Lit Sensor A current correct, 20 … 60 mA.
Green LED (LD1) Blinking Sensor A is being reset.
Red LED (LD2) Blinking Sensor A current is too high and the card is trying to reconnect with correct current. Troubleshooting messages
Red LED (LD2) Lit Sensor A current is too high and power supply to Sensor A has been switched off. Troubleshooting messages
Green LED (LD3) Lit Sensor B current is correct, 20 … 60 mA.
Green LED (LD3) Blinking Sensor B is being reset.
Red LED (LD4) Blinking Sensor B current is too high and the card is trying to reconnect with correct current. Troubleshooting messages
Red LED (LD4) Lit Sensor B current is too high and power supply to Sensor B has been switched off. Troubleshooting messages
A lit red LED on PR‑10701 always indicates a problem. Red LEDs are always turned off in normal operation, whether any sensors are connected or not.
Diagnostic LED functions