Lightning protection kit DKL201 is suitable for the following Vaisala masts with a diameter
of 60 mm (2.36 in) at the top:
- Vaisala DKE100 Series Guyed Frangible
Mast
- Vaisala DKE200 Series Frangible Lattice
Mast
- Vaisala DKP200 Series Tiltable Pole
Mast
- Vaisala Long Pole Mast DKP110
-
Place the air terminal brackets on both sides of the mast. The installation height is
30 cm (11.8 in) from the top of the mast.
| CAUTION To prevent equipment
damage, install the air terminal so that its tip is as high above the sensors as
possible. |
| CAUTION Position the air
terminal bracket so that the mast down conductor and the other cables can be routed down
on the opposite sides of the mast. |
-
Install all the screws except the one on the top right corner of
the brackets. Do not tighten the screws yet.
-
Install the air terminal between the screws so that the bent lower
end of the air terminal comes out from between the upper screws.
-
Install the remaining screw, washers, and nut.
-
Tighten all 9 screws.