Platform update. First release of cloud service support for factory preconfigured devices.
Release date: February 2024
New features and improvements
- Platform and component update:
- Embedded Linux "Yocto" release updated to “Dunfell”.
- Python version updated from 2 to 3.
- Updates to various other components.
- First release of cloud service support,
limited compatibility:
- Available for all AP10 radio variants.
- Real-time data for all supported probes and parameters. No data backfill.
- Limited status and configurations: remote configuration only (Only VaiNet channel and metric/non-metric setting), no local settings.
- Remote firmware update capability.
- Large VaiNet segments are not supported.
Fixes
- Fixed an issue where the loss of power to a CO2 probe on a single data logger would trigger the "Low Battery" alarm in viewLinc on all data loggers connected to the same AP10.
Security enhancements
-
Update Web UI nginx cipher suites to more secure ones.
Compatibility
- AP10 devices in the same network must have firmware v5.0.0 or later.
- Compatible with all RFL100 versions (large VaiNet with RFL100 firmware prior to version 1.8.0 in segment A only).
- Compatible viewLinc Enterprise Server versions 5.2, 5.1, and 5.0.
- Compatible with viewLinc Cloud.
Upgradeability
- Available as firmware update for any AP10 hardware revision G or H.