Support for VaiNet network segments, also known as large VaiNet.
Release date: October 2023
New features and improvements
The ability to configure VaiNet segments (four segments; A, B, C, and D) to enable the setup of large VaiNet systems. Each segment can accommodate up to 256 loggers, using up to 8 APs. The maximum network size can support up to 1024 data loggers.
It is recommended to leave some unused connection capacity in each segment and not plan for a fully maxed out system. For more comprehensive planning guidance, see Guidelines for Large VaiNet Systems (M212596EN). |
Fixes
The following bugs affecting the reliability of AP10 were fixed:
- Fixed an infrequent issue which made the AP10 freeze and require a reboot after changing the VaiNet channel setting.
- Corrected a significant clock time drift issue which could occur after device start up.
- Fixed an issue that caused a 2 second time difference between AP10 time and RFL100.
Compatibility and upgradeability
- Available as firmware update for any AP10 hardware revision G or H.
- Not compatible with other AP10 devices in the same network with firmware older than version 5.0.0.
- Compatible with RFL100 version 1.8.0 in all segments (A to D).
- Compatible with RFL100 versions before version 1.8.0 provided they join segment A.
- Compatible with viewLinc Enterprise Server versions 5.2, 5.1, and 5.0.